Recommended operating conditions, Electrical characteristics, Typical characteristics – Diodes AL8400 /AL8400Q User Manual

Page 3

Advertising
background image

AL8400/ AL8400Q

Document number: DS35115 Rev. 4 - 2

3 of 13

www.diodes.com

August 2012

© Diodes Incorporated

AL8400 /AL8400Q


Recommended Operating Conditions

(@T

A

= +25°C, unless otherwise specified.)


Symbol Parameter Min

Max

Units

V

CC

Supply Voltage Range

2.2

18

V

V

OUT

OUT Voltage Range

0.2

18

I

OUT

OUT

Pin

Current

0.3 15 mA

T

A

Operating Ambient Temperature Range

-40

+125

°C



Electrical Characteristics

(Note 4) (@T

A

= +25°C, V

CC

= 12V, V

OUT

= V

FB

, I

OUT

= 1mA,

unless otherwise specified.)


Symbol Parameter

Conditions

Min

Typ

Max

Units

V

FB

Feedback Voltage

T

A

= +25°C

0.194

0.2

0.206

V

T

A

= -40°C to +125°C

0.190

0.210

FB

LOAD

Feedback Pin Load Regulation

I

OUT

= 1 to 15mA

T

A

= +25°C

3.1

6

mV

T

A

= -40°C to +125°C

10

FB

LINE

Feedback Pin Line Regulation

V

CC

= 2.2V to 18V

T

A

= +25°C

0.1

1.5

mV

T

A

= -40°C to +125°C

2

FB

OVR

Output Voltage Regulation

V

OUT

= 0.2V to 18V, I

OUT

=1mA

(Ref. Figure 1)

T

A

= +25°C

2

mV

T

A

= -40°C to +125°C

3

I

FB

FB Input Bias Current

V

CC

= 18V

T

A

= +25°C

-45

nA

T

A

= -40°C to +125°C

-200 0

I

CC

Supply

Current

V

CC

= 2.2V to 18V, I

OUT

=10mA

T

A

= +25°C

0.48

1

mA

T

A

= -40°C to +125°C

1.5

I

OUT(LK)

OUT

Leakage

Current

V

CC

= 18V, V

OUT

= 18V, V

FB

=0V

T

A

= +25°C

0.1

µA

T

A

= +125°C

1

Z

OUT

Dynamic

Output

Impedance

I

OUT

= 1 to 15mA, f < 1kHz

T

A

= +25°C

0.25

0.4

Ω

T

A

= -40°C to +125°C

0.6

PSRR

Power Supply Rejection Ratio

f = 300kHz, V

AC

= 0.3V

PP

T

A

= +25°C

45

dB

BW

Amplifier Unity Gain Frequency

T

A

= +25°C

600

kHz

G Amplifier

Transconductance

T

A

= +25°C

4500

mA/V

Note:

4. Production testing of the device is performed at +25°C. Functional operation of the device and parameters specified over the operating temperature

range are guaranteed by design, characterization and process control.

Typical Characteristics

Load Regulation

Line Regulation

Advertising