APPENDIX A — FINAL CHECK LIST

£

Is the base unit properly leveled and secured?

£

Are all lubrication points properly lubricated?

£

Is the shut-off valve on to the pump suction open?

£

Is the shut-off valve on the discharge line open?

£

Is the piping properly supported so as to prevent strains on the unit?

£

Is the distribution system purged of debris and air? Is the system filled?

CAUTION: Stuffing Box Damage

Do not run pumps dry. Fill and vent the pump volute
prior to operation.

Failure to follow these instructions indicates a
potentially hazardous situation, which, if not
avoided, may result in property damage.

£

Are the pump and driver shafts properly aligned?

Warning: Rotating Shafts

This pumping system must be disconnected from
the main power supply before check or performing
alignment.

Failure to follow these instructions could result in
serious personal injury, death, and/or property
damage.

 

£

Is the pump rotation correct?

£

Is there adequate ventilation and air circulation?

£

Have all piping connections been made? Have all flanged joints been checked for tightness?