3

PRIMING OPENING

SUCTION

UNION

WARNING

Hazardous voltage

can shock, burn or

cause death.

DANGER

WARNING

CAUTION

Hazardous fluids can

cause personal injury

or property damage.

WARNING

Safety Instructions

TO AVOID SERIOUS OR FATAL PERSONAL

IN-

JURY OR MAJOR PROPERTY DAMAGE, READ AND

FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL

AND ON PUMP.

This is a SAFETY ALERT SYMBOL. When

you see this symbol on the pump or in the

manual, look for one of the following signal

words and be alert to the potential for per-

sonal injury or property damage.
Warns of hazards that WILL cause serious

personal injury, death or major property

damage.
Warns of hazards that CAN cause serious

personal injury, death or major property

damage.
Warns of hazards that CAN cause personal

injury or property damage.

NOTICE: Indicates special instructions which are very

important and must be followed.

THIS MANUAL IS INTENDED TO ASSIST IN THE

INSTALLATION AND OPERATION OF THIS UNIT

AND MUST BE KEPT WITH THE PUMP.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND

WARNINGS PRIOR TO PERFORMING ANY WORK

ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
NOTICE: INSPECT UNIT FOR DAMAGE AND

REPORT ALL DAMAGE TO THE CARRIER

OR DEALER IMMEDIATELY. DO NOT USE

PUMP IF DAMAGE IS SUSPECTED.

UNITS NOT DESIGNED FOR USE

WITH HAZARDOUS LIQUIDS OR

FLAMMABLE GASES.

Description and Specifications

The RJSP and RSPA are end suction, single stage,

self-priming centrifugal pumps for lawn sprinkling,

HVAC systems, and general water transfer.

Casing is cast iron construction with tapped openings

provided for vacuum gauge and casing drain.

Impellers are enclosed design, glass filled Noryl™,

threaded directly on motor shaft.

Standard motors are NEMA standard, 3500 RPM, open

drip proof enclosure.

Maximum Liquid Temperature: 140ºF (60ºC)

Maximum Starts per Hour: 20 – evenly distributed

Piping

Pump MUST be installed horizontally on a solid flat

surface, with discharge on top.

Allow adequate space for servicing and ventilation.

Protect the unit from weather and water damage due to

rain or flooding or freezing temperatures.

Piping should be no smaller than the suction and dis-

charge connections and kept short as possible, avoiding

unnecessary fittings to minimize friction losses.

All piping MUST be independently supported and

MUST NOT place any piping loads on the pump.

NOTICE: DO NOT FORCE PIPING INTO PLACE

AT PUMP SUCTION AND DISCHARGE

CONNECTIONS.

All pipe joints MUST be airtight.

The use of Teflon™ tape, or equivalent, is recommended

for ALL pipe joints.

SUCTION

Total suction lift, including elevation and pipe friction

loss, should not exceed 25 feet of head.

Install an airtight union in the suction line close to the

pump. See Figure 1.

Installation of a foot valve at liquid source is recom-

mended.

NOTICE: FOR INSTALLATIONS WITH LONG

SUCTION PIPING, BOTH A FOOT VALVE

AND A CHECK VALVE ARE

RECOMMENDED.

To avoid air pockets, no part of the piping should be

above the pump suction connection and piping should

slope upward from liquid source.

For installations with long suction piping, fill the suction

pipe with water before connecting to pump.

DISCHARGE

Install a tee at the discharge connection of the pump.

The top opening of the tee is required for initial priming.

See Figure 1.

Figure 1

Wiring and Grounding

Install, ground and wire accord-

ing to local and National Electri-

cal Code requirements.
Install an all leg electrical power

disconnect switch near the

pump.
Disconnect electrical power be-

fore installing or servicing pump.

Safety Instructions

Description and Specifications

Piping

Wiring and Grounding

DISCONNECT SWITCH

DISCHARGE