Xylem IM132 R02 RSPA (FSPA) & RJSP Self-Priming Centrifugal Pumps User Manual

Page 5

Advertising
background image

5

WARNING

Hazardous voltage

can shock, burn or

cause death.

Reassembly – RJSP

Clean and inspect all parts before reassembly.

1. Inspect seal seat bore for wear and debris, clean and

replace as necessary.

NOTICE: MECHANICAL SEAL MUST BE REPLACED

WHENEVER SEAL HAS BEEN REMOVED.

FOLLOW SEAL MANUFACTURER’S

INSTRUCTIONS CAREFULLY.

2. If necessary, seat ring may be lubricated with water or

glycerin to aid in installation. DO NOT contaminate

the seal face. Fully and squarely install the station-

ary seat into the adapter. With a clean, lint free cloth,

CAREFULLY wipe the seat face clean of debris. DO

NOT damage the seal seat face.

3. Reinstall the motor adapter on the motor, making sure

that the motor shaft does not dislocate or damage the

stationary seal seat.

4. Fully and squarely install the seal rotary assembly

against the stationary seat. Be sure rotating seal face

does not drop out of holding collar and DO NOT

damage seal face.

5. On three phase units, impeller MUST be installed with

LOCTITE

®

“Purple”. Hold shaft from rotating, as

explained in the “DISASSEMBLY” section of the

manual, and install impeller by turning CLOCKWISE

until tight against motor shaft shoulder.

6. Replace guidevane. Align to prevent impeller rub.
7. Install new diaphragm and new guidevane seal ring.
8. Install motor and liquid end into casing.
9. Check impeller for binding by rotating the motor

shaft. If binding occurs, loosen casing bolts, readjust

guidevane until impeller hub turns freely. Retighten

casing bolts in a crossing pattern.

10. Replace all drain plugs and motor end components.
11. Reprime and operate according to instructions in the

“OPERATION” section of this manual.

Troubleshooting – All

FAILURE TO DISCONNECT

ELECTRICAL POWER BEFORE

ATTEMPTING ANY MAINTENANCE

CAN CAUSE SHOCK, BURNS OR

DEATH.

SYMPTOM
MOTOR NOT RUNNING:

See Probable Causes 1 through 5.
LITTLE OR NO WATER DELIVERED:

See Probable Causes 3, 4, 6 through 12, 15.
EXCESSIVE NOISE AND VIBRATION:

See Probable Causes 3, 6, 7, 10, 12, 13, 14.
PROBABLE CAUSES

1. Motor thermal protector tripped.
2. Open circuit breaker or blown fuse.
3. Impeller binding.
4. Motor improperly wired.
5. Defective motor.
6. Pump is not primed, air or gases in pumpage.
7. Discharge, suction plugged or valve closed.
8. Incorrect rotation. (3 phase only)
9. Low voltage or phase loss.
10. Impeller worn or plugged.
11. System head too high.
12. NPSHA too low – excessive suction lift or loss.
13. Discharge head too low – excessive flow rates.
14. Pump, motor or piping loose.
15. End of suction piping not submerged.

Reassembly – RJSP

Troubleshooting – All