Xylem IM132 R02 RSPA (FSPA) & RJSP Self-Priming Centrifugal Pumps User Manual

Page 4

Advertising
background image

4

Electrical supply MUST match pump’s name-

plate specification. Incorrect voltage can cause

fire or damage to the motor and voids warranty.
Motors without built-in protection MUST be

provided with contactors and thermal overloads

for single phase motors, or starters with heaters

for three phase motors. See motor nameplate.

Follow motor manufacturer’s wiring diagram on the

motor nameplate or terminal cover carefully.

Use only copper wire to motor and ground. The ground

wire MUST be at least as large as the wire to the motor.

Wires should be color coded for ease of maintenance.

RECOMMENDED MINIMUM WIRE SIZE

Distance from Service Entrance to Motor

HP

50 Ft. (15 m) 100 Ft. (30 m) 150 Ft. (46 m) 200 Ft. (61 m)

115 V 230 V 115 V 230 V 115 V 230 V 115 V 230 V

¾ 12 14 10 14 8 14 6 12

1 12 14 8 14 8 12 6 12

1½ 10 14 8 14 – 12 – 10

2 10 14 8 14 – 12 – 10

3 – 12 – 12 – 10 – 10

FAILURE TO PERMANENTLY

GROUND THE PUMP, MOTOR AND

CONTROLS BEFORE CONNECT-

ING TO ELECTRICAL POWER CAN

CAUSE SHOCK, BURNS, OR DEATH.

Rotation

NOTICE: INCORRECT ROTATION MAY CAUSE

DAMAGE TO THE PUMP AND VOIDS THE

WARRANTY.

Correct rotation is right hand, CLOCKWISE when

viewed from the motor end.

Operation

OPERATION WITHOUT PRIME, OR

AGAINST A CLOSED DISCHARGE

VALVE, CAN GENERATE HOT WA-

TER OR STEAM CAUSING INJURY

OR PROPERTY DAMAGE.
NOTICE: DO NOT OPERATE PUMP

WITHOUT PRIME OR SEAL

DAMAGE WILL RESULT.

Prime pump by filling pump and piping through

opening in top of tee with clean water. See Figure 1.

Install pipe plug in top of tee using Teflon™ tape or

equivalent.

NOTICE: IF PUMP IS DRAINED OR SHUT OFF

DURING PRIMING PERIOD, CASING

MUST BE REFILLED BEFORE

RESTARTING PUMP.

Start the pump and partially open discharge valve and

wait for system pressure to stabilize. If system pressure is

surging, or prolonged pressure drop is experienced, the

system may not be completely primed.

WARNING

Hazardous voltage

can shock, burn or

cause death.

WARNING

Extreme heat can

cause personal injury

or property damage

WARNING

Hazardous

voltage

Maintenance – All Models

FAILURE TO DISCONNECT

ELECTRICAL POWER BEFORE

ATTEMPTING ANY MAINTENANCE

CAN CAUSE SHOCK, BURNS OR

DEATH.

No lubrication is required on pump.

For motor lubrication, refer to and

follow manufacturer’s instructions.

SEASONAL SERVICE

To REMOVE pump from service, turn power off,

remove all drain plugs and drain all piping.

To RETURN pump to service, replace all drain plugs

using Teflon™ tape or equivalent.

Reconnect suction line if removed, examine union and

repair if necessary.

Reprime and operate pump following all instructions

and warnings in the “OPERATION” section of manual.

Disassembly – RJSP

FAILURE TO DISCONNECT

ELECTRICAL POWER BEFORE

ATTEMPTING ANY MAINTENANCE

CAN CAUSE SHOCK, BURNS OR

DEATH.

1. Remove foot bolt (10).
2. Remove casing bolts (12).
3. Remove back pull-out assembly from casing (2).
4. Remove guidevane seal ring (3) and diaphragm (4).
5. Remove guidevane screws (5) from adapter (11).
6. Remove motor end plug or cover.
7. Restrain motor shaft from rotation by utilization of

the screwdriver slot, or

7

16

" shaft flats, accessible at the

motor shaft end.

8. Remove impeller (7), turning COUNTER-

CLOCKWISE.
9. Using two screwdrivers, pry off rotary section of

mechanical seal (8). Discard. See Figure 2.

10. Remove motor adapter bolts (13) and remove motor

adapter from motor.

11. Push stationary seat of mechanical seal out of

motor adapter. Discard seal seat.

Figure 2

Rotation

Maintenance – All Models

Disassembly – RJSP

WARNING

Hazardous voltage

can shock, burn or

cause death.

Operation

Advertising