Seal type

Parameter

Value

Flushed single seals

1,3,4,

pH range limits

pH 7–9

Liquid temperature range

0˚F to 250˚F (-18˚C to 121˚C)

Table notes

1. An external flush is required on low pressure systems that contain a high

concentration of abrasives.

2. For operating temperatures above 250°F, a cooled flush is required and is

recommended for temperatures above 225°F for optimum seal life. On closed
systems, cooling is accomplished by inserting a small heat exchanger in the flush line
to cool the seal flushing fluid.

3. Flush-line filters and sediment separators are available on request.
4. Use a standard seal on closed or open systems that are relatively free of dirt and/or

other abrasive particles.

Product Description

10

Series 580 Installation, Operation, and Maintenance Manual