Install the impeller, Reinstall the pump assembly, Screw torque values – Xylem 580-IM Marlow Series 580 User Manual

Page 22: Dealer servicing

Advertising
background image

10. Volute gasket

11. Impeller washer

12. Shaft sleeve

13. Shaft

Figure 2: Standard mechanical seal

Install the impeller

1. Install the impeller, impeller washer, lockwasher, and capscrew.
2. Tighten the capscrew according to the Capscrew torque values table.

Reinstall the pump assembly

1. Install a new volute gasket.
2. Install the pump assembly into the volute.
3. Tighten the volute capscrews according to the Capscrew torque table.
4. Install a seal flushing tube if it is used.
5. Install the drain plug and close the drain valve.
6. Open the isolation valves and inspect the pump for leaks.
7. Return the pump to service if it is not leaking.

Screw torque values

Capscrew torque in ft-lb (Nm)

Capscrew

type

Head

marking

Capscrew diameter (in inches)

1/4

5/16

3/8

7/16

1/2

5/8

3/4

7/8

1

SAE grade

2

6 (8)

13 (18)

25 (34)

38 (52)

60 (81)

120 (163) 190 (258) 210 (285) 300 (407)

Brass and

stainless

steel

or

4 (5)

10 (14)

17 (23)

27 (37)

42 (57)

83 (113)

130 (176) 200 (271) 300 (407)

SAE grade

5

10 (14)

20 (27)

35 (47)

60 (81)

90 (122)

180 (244) 325 (440) 525 (712) 800

(1085)

Dealer servicing

If trouble occurs that cannot be rectified, contact your local Xylem representative and be
prepared to provide this information:
1. Complete nameplate data of pump and motor
2. Suction and discharge pipe pressure gauge readings
3. Ampere draw of the motor
4. A sketch of the pump hook-up and piping

Maintenance

20

Series 580 Installation, Operation, and Maintenance Manual

Advertising