Remove the impeller, Remove the mechanical seal (580 and 580-f), Pre-assembly inspections – Xylem 580-IM Marlow Series 580 User Manual

Page 20: Replacement guidelines

Advertising
background image

WARNING:
Pressurized device. Make sure that the internal pressure is relieved
before you continue.

3. Remove the seal flushing tube if it is used.
4. Remove the volute capscrews.
5. Remove the pump assembly from the volute.

Remove the impeller

WARNING:
Never apply heat to remove an impeller. The use of heat may cause an explosion due to
trapped liquid, resulting in severe physical injury and property damage.

CAUTION:
Wear heavy work gloves when you handle impellers. The sharp edges can cause physical
injury.

1. Remove the impeller capscrew.
2. Remove the lockwasher and the washer.
3. Remove the impeller.

Remove the mechanical seal (580 and 580-F)

1. Remove the rotating portion of the seal.

If necessary, use a screwdriver to loosen the rubber ring.

2. Remove the seal insert, the insert gasket, and the retainer if it is used.

Pre-assembly inspections

Guidelines

Before you assemble the pump parts, make sure you follow these guidelines:

• Inspect the pump parts according to the information in these pre-assembly topics

before you reassemble your pump. Replace any part that does not meet the required
criteria.

• Make sure that the parts are clean. Clean the pump parts in solvent in order to remove

oil, grease, and dirt.

NOTICE: Protect machined surfaces while you clean the parts. Failure to do so may
result in equipment damage.

Replacement guidelines

Impeller replacement

This table shows the criteria for replacing the impeller:

Impeller parts

When to replace

Impeller vanes

• When grooved deeper than 1/16 in. (1.6 mm), or
• When worn evenly more than 1/32 in. (0.8 mm)

Vane edges

When you see cracks, pitting, or corrosion damage

Maintenance

18

Series 580 Installation, Operation, and Maintenance Manual

Advertising