Maintenance

Lubrication

The pump motor has been lubricated at the factory. Keep the motor properly lubricated in
accordance with the motor manufacturer's instructions.

Disassembly

Disassembly precautions

WARNING:
• This manual clearly identifies accepted methods for disassembling units. These methods

must be adhered to. Trapped liquid can rapidly expand and result in a violent explosion
and injury. Never apply heat to impellers, propellers, or their retaining devices to aid in
their removal.


• Always disconnect and lock out power to the driver before you perform any installation

or maintenance tasks. Failure to disconnect and lock out driver power will result in
serious physical injury.

• Crush hazard. The unit and the components can be heavy. Use proper lifting methods

and wear steel-toed shoes at all times.

NOTICE:
Make sure that all replacement parts are available before you disassemble the pump for
overhaul.

Drain the pump

CAUTION:
• Allow all system and pump components to cool before you handle them to prevent

physical injury.

1. Close the isolation valves on the suction and discharge sides of the pump.

You must drain the system if no valves are installed.

2. Open the drain valve.

Do not proceed until liquid stops coming out of the drain valve. If liquid continues to
flow from the drain valve, the isolation valves are not sealing properly and you must
repair them before you proceed.

3. Leave the drain valve open and remove the drain plug located on the bottom of the

pump housing.
Do not reinstall the plug or close the drain valve until the reassembly is complete.

4. Drain the liquid from the piping and flush the pump if it is necessary.
5. Disconnect all auxiliary piping and tubing.

Remove the pump assembly

1. Loosen the volute capscrews but do not remove them.
2. Use the capscrews in the jackscrew holes in order to loosen the pump assembly from

the volute.

Maintenance

Series 580 Installation, Operation, and Maintenance Manual

17

Advertising