8: DIAGRAMS

(continued)

Typical Motor Nameplate Showing Service Factor Amps (SF AMPS)

8: DIAGRAMS

Labels found on the Controller Access Cover:

In this example, use the 4.2 Amp setting indicated on the Motor Overload Setting Table. This setting is used to account
for any voltage fluctuation.

Service Factor Amps (SF AMPS)
that are used to set the Motor
Overload Setting Switches.

Motor Overload Setting Label
Use this label to choose the correct Motor Overload Switch
Setting. This label is found under the controller access cover.

Status Code

Label

Use this label

to diagnose any

system errors.

This label is

found on the

side of the

controller

access cover.

Motor Overload Setting

WARNING

Disconnect Power And Wait For LED Indicator To Turn

Off Before Touching Motor Overload Setting Switches.

1 = UP 0 = DOWN

DIP Switch Setting

Motor Overload Setting (Amps)

1 2 3 4

1AB2

2AB2

1 1 1 1

2.5

4.6

1 1 1 0

2.8

5.2

1 1 0 1

3.3

5.3

1 0 1 1

3.5

5.8

0 1 1 1

3.8

6.5

0 0 0 0

4.2

6.9

Status Codes*

Green Light Codes

Constant

Standby/Low Voltage

Blinking

Pump Running

Red Light Codes

Constant

Replace Controller

1 Blink

No Water/Loss Of Prime

2 Blinks

Tank Water-Logged

3 Blinks

Pressure Sensor Fault

4 Blinks

Pump or Motor Bound

5 Blinks

Short Circuit

6 Blinks

Ground Fault

7 Blinks

High Temperature

8 Blinks

Over Voltage (>264V)

9 Blinks

Motor Overload

*No Light - No/Very Low Voltage

Application Type Switch Setting

WARNING

DIP Switch Setting

1 = UP 0 = DOWN

1 2 3 4

Minimum Speed (Hz)

Ramp Setting

1 1 1 1 *

10

Slow

1 1 1 0 *

10

Medium

1 1 0 1 *

10

Fast

1 0 1 1

30

Slow

0 1 1 1

30

Medium

0 0 0 0

30

Fast

*THESE SETTINGS ARE NOT TO BE USED WITH SUBMERSIBLE PUMPS.

Disconnect Power And Wait For LED Indicator To Turn

Off Before Touching Application Setting Switches.

Application Switch Setting Label
Use this label to choose the correct
Application Switch Setting. This label is
found under the controller access cover.