SMVT Installation, Operation and Maintenance Manual

III. Product Description

Description

This section provides a general description of the Goulds Water Technology Model SMVT
and key engineering specifications.

Overview

The Goulds Water Technology Model SMVT pumps are surface mounted, multi-stage,
vertical turbine pumps.
Pump impellers are closed, shaft driven, and held in position by a positive-locking taper

collet.
Suction and discharge connections are ANSI standard 3 inch 125# or 250# and 4 inch
125# or 250# flange type.
Pumps are available with standard ODP or TEFC motors.

Intended Use

Commercial Applications:

Booster Units
High Rise Building Water Applications
HVAC

Municipal Applications:

Package Pump Stations
Booster Stations
Water Treatment Applications

Irrigation Applications:

Turf Irrigation
Golf Courses
Stadiums
Greenhouses/ Nurseries
Sprinkler Systems

Engineering Data

Torque Values
Table 3: Torque Values
Description

Torque (ft.-lbs.)

Motor Bolts – 3, 5, 7.5 HP motors

20

Motor Bolts – 10 to 40 HP motors

45

Motor Bolts – 50, 60, 75 HP motors

70

Casing Bolts

120

Bowl Bolts

45

Coupling Bolts

28

Liquid Temperature:

Liquid temperature from -13ºF (-25ºC) to 150ºF (65ºC)

Note: Pump and piping should be protected from skin contact if temperature is less than

10ºC or higher than 40ºC