SMVT Installation, Operation and Maintenance Manual
17
Typical Plumbing and Installation
Figure 14: Typical Plumbing and Installation
Final Piping Check
After connecting the piping to the pump, rotate the motor shaft to make sure that there is
no binding.
Wiring
Warning: DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE
INSTALLING OR SERVICING PUMP.
Warning: Install ground and wire according to local and National Electrical
Code requirements.
Warning: Install an all leg electrical power disconnect switch near the pump.
Warning: Electrical supply MUST match motor’s nameplate specifications.
Incorrect voltage can cause fire, damage the motor and void the warranty.