Xylem IM158 R04 Model SMVT User Manual

Page 11

Advertising
background image

SMVT Installation, Operation and Maintenance Manual

9

Maximum Working Pressure

Table 4: Maximum Working Pressure

Model

Maximum Pressure

175 psi

400 psi

SM1

up to (3) stages

more than (3) stages

SM2

up to (3) stages

more than (3) stages

SM3

up to (3) stages

more than (3) stages

SM4

up to (3) stages

more than (3) stages

SM5

up to (4) stages

more than (4) stages

SM6

up to (4) stages

more than (4) stages

Starts per hour:

Table 5: Electric Data

2

HP

Motor Frame

RPM

Voltage

Phase

Hz

Start/Hour

5

182TC 230 1

270

184TC

230/460

3

165

7.5

182TC 230 1

210

213TC

3

150

10

213TC

1 210

215TC

135

15

215TC

105

20

254TC

150

256TC

75

25

256TC

135

284TSC

3500

60

30

30

284TSC

230/460

60

286TSC

3

30

40

286TSC

45

324TSC

30

50

324TSC

45

326TSC

25

60

326TSC

30

364TSC

25

75

364TSC

2

365TSC

2

2

Electric data is based on Goulds Water Technology choice motors. Other manufacturer’s motors may have

different values.