Xylem IM180 R3 Standard and Dual Voltage Motors User Manual

Page 10

Advertising
background image

8

CentriPro Motors Installation, Operation and Maintenance Manual

Connection Diagram For Single Phase Motors

Line 2

Blue

Line 1

Yellow

Starter Box

O.L.B.

CR

CS

S.R.

R

B

Y

G

A.C.

M.C.

Motor

SYMBOL

Motor : Single Phase Induction Motor

M.C. : Main Coil

A.C.

: Auxiliary Coil

B

: Motor Lead Black

R

: Motor Lead Red

Y

: Motor Lead Yellow

G

: Motor Ground Lead Green

CR

: Running Capacitor

CS

: Starting Capacitor

S.R.

: Starting Voltage Realy

O.L.B. : Overload Protection Circuit

Breaker

Figure 4

Table 3 — Performance Data of Single Phase Submersible Motors

6" MOTOR, 3600 RPM

Output

(HP)

5

7½ 10 15

Voltage-Frequency

230V / 60 Hz

230V / 60 Hz

230V / 60 Hz

230V / 60 Hz

No Load Current

(A)

8.8

8.3

12.0

16.1

No Load Loss

(W)

1184 1428 1544 2050

Load

(%)

50 75 100 115 50 75 100 115 50 75 100 115 50 75 100 115

Current

(A)

14.6 18.9 24 27.5 19.5 26.7 36 41 25.5 35.5 50 58 38.1 52.7 72 85

Efficiency

(%)

66.2 72.2 74.8 74.8 67.6 72.5 72.9 71.5 67.8 73.1 73.6 72.0 70.8 74.7 73.7 71.3

Power Factor

(%)

84.0 89.0 91.2 92.0 92.5 94.5 94.9 94.3 88.9 91.8 93.2 93.5 90.2 92.7 93.2 92.4

Slip

(%)

1.5 2.2 3.0 3.6 1.8 2.9 4.2 5.5 1.7 2.8 4.1 5.2 2.1 3.3 4.9 6.2

Full Load Torque

(ft•lbs)

7.53

11.42

15.23

23

Breakdown Torque

(ft•lbs)

15.5

22.0

27.4

45

Locked Rotor Torque

(ft•lbs)

12.5

18.3

21.3

34

Locked Rotor Current

(A)

124 167 202 275

Locked Rotor Code

(KVA)

G

F

E

D

Rated Input

(W)

4987

7675

10135

15180

Current at SF 1.15

(A)

27.5

41

58

85

Input at SF 1.15

(W)

5735

8950

11830

18050

Specifications of

440 VAC

440 VAC

440 VAC

440 VAC

Running Capacitor

30μFD 40μFD 50μFD 70μFD

Specifications of

330 VAC

330 VAC

370 VAC

370 VAC

Starting Capacitor 200μFD 250μFD 350μFD 450μFD

Load

Characteristics

Operation (continued)

Advertising