Xylem IM180 R3 Standard and Dual Voltage Motors User Manual

Page 12

Advertising
background image

10

CentriPro Motors Installation, Operation and Maintenance Manual

Operation (continued)

Table 5 — 6" - 10" Three Phase Resistance, KVA, Efficiency, Fuses

Motor HP kW Volts Phase F.L. KVA Line - Line

Time Delay Fuse

Order No.

Efficiency % Code

Resistance

Standard

Dual Ele.

6M058

5 3.7 200

75.9

K

0.618

50

25

6M052

5

3.7

230

76.8

K

0.806

45

20

6M054

5

3.7

460

76.8

K

3.050

25

10

6M078 7.5 5.5 200

77.9

J

0.504

80

40

6M072

7.5

5.5

230

78.5

J

0.651

70

30

6M074

7.5

5.5

460

78.5

J

2.430

35

15

6M108 10 7.5 200

79.7

K

0.315

100

50

6M102

10

7.5

230

79.3

K

0.448

90

40

6M104

10

7.5

460

79.3

K

1.619

45

20

6M158 15 11 200

81.7

K

0.213

175

70

6M152

15

11

230

81.7

K

0.312

150

60

6M154

15

11

460

81.7

K

1.074

70

30

6M208 20 15 200

82.7

J

0.189

200

90

6M202

20

15

230

83.2

J

0.258

175

70

6M204

20

15

460

3 83.2 J 0.861 90

35

6M258 25 18.5 200

82.0

K

0.146

250

110

6M252

25

18.5

230

83.0

K

0.210

225

90

6M254

25

18.5

460

83.0

K

0.666

110

45

6M308 30 22 200

82.9

J

0.119

300

125

6M302

30

22

230

82.5

K

0.166

250

100

6M304

30

22

82.5

K

0.554

125

50

6M404

40

30

84.0

H

0.446

175

70

66M504

50

37

82.5

J

0.388

225

90

86M504

50

37

84.1

H

0.331

200

90

86M604

60

45

460

84.7

H 0.278

250

110

8M754

75

55

84.9

H

0.218

300

125

8M1004 100

75

85.2

H

0.164

400

175

8M1254 125

90

84.2

G

0.132

500

225

8M1504 150 110

85.6

G

0.115

600

250

10M2004 200 150

87.2

F

0.0929

800

350

Advertising