X. motor cooling, temperature ratings, Minimum flow rates for proper motor cooling – Xylem IM180 R3 Standard and Dual Voltage Motors User Manual

Page 15

Advertising
background image

CentriPro Motors Installation, Operation and Maintenance Manual

13

FLOW SLEEVE

X. Motor Cooling, Temperature Ratings

Six (6) inch canned design motors from 5 – 40 HP will operate in water up to 95º

F (35º C), without any de-rating of horsepower, with a minimum flow rate of .5 ft./

sec. past the motor. 6" – 50 HP and all 8" – 10" motors can operate in 77º F (25º C)

water with .5'/sec velocity past the motor.

Minimum Flow Rates For Proper Motor Cooling

Well or

CP = 5.5" Dia.

FE = 5.38" Dia.

CP = 7.52" Dia.

Sleeve

6" CP Motor

6" FE Motor

8" CP Motor

Diameter

.5'/sec.

.5'/sec.

.5'/sec.

(inches)

GPM Required

6 7

9

7 23

25

8 41

45

9

10 85

90

53

12 139

140

107

14 198

200

170

16 276

280

313

Multiply gpm by .2271 for m

3

/Hr.

Multiply gpm by 3.785 for l/min.

Motor Cooling, Temperature Ratings