X. motor cooling, temperature ratings, Minimum flow rates for proper motor cooling – Xylem IM180 R3 Standard and Dual Voltage Motors User Manual
Page 15
CentriPro Motors Installation, Operation and Maintenance Manual
13
FLOW SLEEVE
X. Motor Cooling, Temperature Ratings
Six (6) inch canned design motors from 5 – 40 HP will operate in water up to 95º
F (35º C), without any de-rating of horsepower, with a minimum flow rate of .5 ft./
sec. past the motor. 6" – 50 HP and all 8" – 10" motors can operate in 77º F (25º C)
water with .5'/sec velocity past the motor.
Minimum Flow Rates For Proper Motor Cooling
Well or
CP = 5.5" Dia.
FE = 5.38" Dia.
CP = 7.52" Dia.
Sleeve
6" CP Motor
6" FE Motor
8" CP Motor
Diameter
.5'/sec.
.5'/sec.
.5'/sec.
(inches)
GPM Required
6 7
9
–
7 23
25
–
8 41
45
9
10 85
90
53
12 139
140
107
14 198
200
170
16 276
280
313
Multiply gpm by .2271 for m
3
/Hr.
Multiply gpm by 3.785 for l/min.
Motor Cooling, Temperature Ratings