Xylem ECOCIRC EB EBV IM User Manual

Page 17

Advertising
background image

en

17

8. Maintenance/Disassembly

Pumps are subject to wear. If the pump is blocked or grinding noises are audible, check

the pump and replace it if necessary. Procedure:

- Disconnect pump from the mains.
- Close the connection lines.

- Loosen the union nut and remove the motor (Residual water
may leak out of the rotor cavity. Prevent the electrical
connection to the pump from getting wet.).

When replacing non-LOWARA motors, use the additionally included flat seal. The groove
for holding the flat seal in non-LOWARA pump housings has an additional ridge that can
cause leakage when used with an O-ring seal.

9. Troubleshooting

Work on electrical parts may only be performed by authorized

specialists.

Problem Cause

Solution

Pump not running

- Not connected or

connected incorrectly

- Pump too hot, dry

operation- or overheating
protection active

- Pump blocked

- Connect correctly

- Allow to cool, pump
restarts automatically

- See section 8
“Maintenance/Disassembly”

Pump is noisy

- Not thoroughly bled

- Foreign objects in pump

- Worn bearing

- See section 7.2 “Getting

started”

- See section 8

“Maintenance/Disassembly”

- Replace pump


Malfunctioning pumps can be returned to the manufacturer‘s address. The manufacturer
will refuse to accept packages with unpaid shipping or invoices for repair. The
manufacturer grants a two-year guarantee under the condition of correct installation and

proper use.