8 connecting the voltage supply, 1 iq sensor net (line power version), Connecting the voltage supply -30 3.8.1 – YSI IQ S ENSOR N ET System 182 User Manual

Page 44

Advertising
background image

Installation

System 182

3 - 30

ba76022e01

12/2011

3.8

Connecting the voltage supply

Note
The two following paragraphs describe how to connect both models of
the IQ S

ENSOR

N

ET

Universal Transmitter to the voltage supply. How

to connect additional power supply modules is described in the
operating manual of the respective power supply module.

3.8.1

IQ S

ENSOR

N

ET

(Line power version)

Warning

If the power supply is incorrectly connected, it may represent a
danger to life from electric shock. Pay attention to the following
points during installation:
The IQ S

ENSOR

N

ET

Universal Transmitter may only be

connected by a trained electrician.

The connection of the IQ S

ENSOR

N

ET

Universal Transmitter to

the power supply may only be carried out when it is not
carrying any voltage.

The power supply must fulfill the specifications given on the

nameplate and in chapter 9 T

ECHNICAL

DATA

.

When installed in a building, a switch or power switch must be

provided as an interrupt facility for the System 182.
The interrupt facility must

– be installed in the vicinity of the IQ S

ENSOR

N

ET

Universal

Transmitter, easily accessible by the user, and

– be labeled as the interrupt facility for the

IQ S

ENSOR

N

ET

Universal Transmitter.

After the IQ S

ENSOR

N

ET

Universal Transmitter has been

installed, it may only be opened if the line voltage has been
switched off beforehand.

Materials required

 Wire end sleeves, suitable for the power line, with suitable crimping

tool

 1 x screwed cable gland with sealing ring (scope of delivery of the

Universal Transmitter).

Tools

 Cable stripping knife

 Wire stripper

 Phillips screwdriver

 Small screwdriver.

Advertising