Ii. fc220 specifications – Xylem FC220 OPEN CHANNEL FLOW MONITOR User Manual

Page 5

Advertising
background image

Global Water

800-876-1172

globalw.com

- 5 -

II.

FC220 Specifications:

Power Requirements:

12VDC or 18-24VDC Input, +/-10%

Supply Current:

13mA + Sensor Current + Backlight + 4-20mA Output

150mA Maximum Total Current

Backlight Current:

23mA when on

Internal Fuse:

315mA

Power Adaptor:

18VDC Universal Power Supply, 90-220VAC Input

Equation Formats:

Manning’s Equation for Round Pipes

Manning’s Equation for Rectangular Channels

Standard Flow Equation: Q=A*(B+Ch)^D

3

rd

Order Polynomial: Q=A+Bh+Ch^2+Dh^3

Stored Flumes:

H Type: 0.5, 0.75, 1.0, 1.5, 2.0

HS Type: 0.4, 0.6

Parshall: 1”, 2”, 3”, 6”, 9”, 12”, 24”, 36”, 48”, 60”, 72”

Palmer-Bowlus: 4”, 6”, 8”, 10”, 12”, 15”, 18”, 24”, 30”, 36”

Trapezoidal: 60º

Stored Weirs:

Rectangular: 1’, 2’ 3,

V-Notch: 22.5º, 30º, 45º, 60º, 90º, 120º

Cipolletti: 1’, 1.5’, 2’, 3’, 4’

Lookup Table:

One, Factory Programmable Only

Output Relays:

4 Independent SPDT Relays, Pulse On Time = 1 Second

Contact Rating:

8A @ 250VAC, 5A @ 30VDC Resistive

Level Sensor Input:

2-Wire or 3-wire, 4-20mA, 0-5VDC, 0-1VDC

Output:

4-20mA Scalable

Display/Keypad:

16 Character x 2 Line Backlit LCD, 8-Button Tactile Keypad

Flow Capacity:

7 Digit Maximum, Auto-Floating point

Totalizer Capacity:

9 Digit Maximum

Auto-Floating Point, Engineering notation supported

Max Volume = 1.0995E12 Cubic Feet (1.0995 x 10^12 Ft³)

Level Capacity:

5 Digit Maximum

Display Resolution:

3 Decimal Places Maximum, Auto-Adjusting

Accuracy:

Sensor Accuracy + Equation/Table Error + 0.1% + 1 Digit

Level Units:

Feet, Inches, Meters, Centimeters

Volume Units:

Cubic Feet, Gallons, Million Gallons, Cubic Meters, Liters

Time Units:

Seconds, Minutes, hours, Days

Flow Units:

20 Combinations of Volume and Time Units Above

Dimensions:

7.1”W x 5.1”H x 1.4D (180mm x 130mm x 35mm)

Weight:

1 lb

Advertising