Manual – Xylem Expert 3400 User Manual

Page 12

Advertising
background image

12

Manual

Manual Expert 1400/3400 GB 0704

MJK Automation A/S
Byageren 7
DK-2850 Naerum
Denmark
Tel.: +45 45 56 06 56
Fax: +45 45 56 06 46
[email protected]
www.mjk.com

MJK Expert™ 1400 Level Transmitter has

about the same specifications as the 7070

model. In addition it has a ceramic, capaci-

tive measuring system with a much higher

accuracy. Furthermore, Expert™ 1400 is

approved for use in explosion hazardous

areas: ATEX Ex ia IIC T6.
Model 1400 is very useful for level measure-

ments in for example ground water bore

holes and in-fill sites, where explosion proof

transmitters are required.

Specifications

MJK Expert™ 1400 Hydrostatic Level Transmitter

Nominal measuring range

0 - 0,3 m

0 - 1 m

0 - 3 m

0 - 5 m

0 - 10 m

0 - 30 m

0 - 100 m

0 - 300 m

Measuring principle

Ceramic capacitive, relative pressure

Min. programmable range

0 - 0,3 m 0 - 0,3 m

0 - 1 m

0 - 3 m

0 - 3 m

0 - 10 m

0 - 30 m

0 - 90 m

Max. programmable range

0 - 1 m

0 - 1 m

0 - 3 m

0 - 10 m

0 - 10 m

0 - 30 m

0 - 100 m

0 - 300 m

Max. overpressure

4 bar

4 bar

6 bar

10 bar

10 bar

18 bar

40 bar

40 bar

Temperature range

-20 °C to 40 °C

Temp. deviation, 0 point

Better than ± 0.02 % / °C

Temperature deviation, FS

Better than ± 0.01 % / °C

Linearity / Stability

Better than ± 0.2 % FS / ± 0.2 % FS

Measurement accuracy

Better than ± 0.1 % FS @ +10 to 30 °C
Better than ± 0.2 % FS @ full temperature range

Long time stability

Better than ± 0.1 % FS per year

Materials

Housing: stainless steel (AISI 316 L), diaphragm: 96,6 % Al

2

O

3

/Cell packing: Viton

®

Supply voltage

10 - 30 V DC (12 - 30 V DC for cable lengths above 100 m)

Output signal

2-wire 4 - 20 mA (passive transmitter)

Cable

2 × 0,5 mm

2

(pressure) + 5 x 0,15 mm

2

(data), shielded, PUR insulation

Cable length

12 m

12 m

12 m

12 m

12 m

35 m

110 m

320 m

Enclosure

IP 68, withstands a static pressure equal to max. overpressure.

Approvals

ATEX: II 2G EEx ia IIC T5/T6 and CE: EN61000-6-3/-4:2001, EN61000-6-1/-2:1999,
EN50014:1997 E, EN50020:2002

Can be delivered with other cable lengths on request.

Dia. 24 mm

73 mm

Order Numbers

Dimensions and

Accessories

Cable bracket for MJK Expert™ 1400
Level Transmitter
(1 pc. is delivered with each transmitter)

MJK Expert™ 1400
Level Transmitter

152 mm

65 mm

Dia. 22 mm

Data Sheet for

Expert™ 1400 Level

Transmitter

Order Numbers

2011

Expert™ 1400, range 0 - 0,3 mWG

2016

Expert™ 1400, range 0 - 30 mWG

2012

Expert™ 1400, range 0 - 1 mWG

2017

Expert™ 1400, range 0 - 100 mWG

201

Expert™ 1400, range 0 - 3 mWG

2018

Expert™ 1400, range 0 - 300 mWG

2014

Expert™ 1400, range 0 - 5 mWG

20225

Expert™ 1400, special meas. range

2015

Expert™ 1400, range 0 - 10 mWG

All 1400 transmitters are Atex approved.