Manual – Xylem Expert 3400 User Manual

Page 13

Advertising
background image

1

Manual

Manual Expert 1400/3400 GB 0704

MJK Automation A/S
Byageren 7
DK-2850 Naerum
Denmark
Tel.: +45 45 56 06 56
Fax: +45 45 56 06 46
[email protected]
www.mjk.com

MJK Expert™ 3400 Level Transmitter is

designed for use in waterworks, sewage

treatment plants and industrial applications

where accurate and long term stable level

measuring is required. It is very robust and

designed for applications in rough envi-

ronments with aggressive chemicals and

aggressive fluids.
A major design feature is the programming

facility. With a standard USB interface and

a laptop computer, the servicing transmit-

ter can be programmed on-the-fly to the

required measuring range.

Specifications

60 mm

236 mm

Dimensions and

Accessories

Cable bracket for MJK model 3400
(1 pc. is delivered with each transmitter)

Order numbers

MJK Expert™ 3400
Level Transmitter

135 mm

32 mm

Dia. 50 mm

1” NPT

Dia. 50 mm

135 mm

36 mm

Data Sheet for

Expert™ 3400 Level

Transmitter

Order Numbers

2051

Expert™ 3400, range 0 - 0.3 mWG

2057

Expert™ 3400, range 0 - 100 mWG

2052

Expert™ 3400, range 0 - 1 mWG

2058

Expert™ 3400, range 0 - 300 mWG

205

Expert™ 3400, range 0 - 3 mWG

2061

Expert™ 3400, range 0 - 0.3 m 1" RG top

2054

Expert™ 3400, range 0 - 5 mWG

2062

Expert™ 3400, range 0 - 1 m 1" RG top

2055

Expert™ 3400, range 0 - 10 mWG

206

Expert™ 3400, range 0 - 3 m 1" RG top

2056

Expert™ 3400, range 0 - 30 mWG

20225

Expert™ 3400 w/ special meas. range

MJK Expert™ 3400 Hydrostatic Level Transmitter

Nominal measuring range

0 - 0,3 m

0 - 1 m

0 - 3 m

0 - 5 m

0 - 10 m

0 - 30 m

0 - 100 m

0 - 300 m

Measuring principle

Ceramic capacitive, relative pressure

Min. programmable range

0 - 0,3 m 0 - 0,3 m

0 - 1 m

0 - 3 m

0 - 3 m

0 - 10 m

0 - 30 m

0 - 90 m

Max. programmable range

0 - 1 m

0 - 1 m

0 - 3 m

0 - 10 m

0 - 10 m

0 - 30 m

0 - 100 m

0 - 300 m

Max. overpressure

4 bar

4 bar

6 bar

10 bar

10 bar

18 bar

40 bar

40 bar

Temperature range

-20 °C to 40 °C

Temp. deviation, zero oint

Better than ± 0.02 % / °C

Temperature deviation, FS

Better than ± 0.01 % / °C

Linearity / Stability

Better than ± 0.2 % FS / ± 0.2 % FS

Measurement accuracy

Better than ± 0.1 % FS @ +10 to 30 °C. Better than ± 0.2 % FS @ full temperature range

Long time stability

Better than ± 0.1 % FS per year

Materials

Housing: stainless steel (AISI 316 L), diaphragm: 96,6 % Al

2

O

3

/Cell packing: Viton

®

Supply voltage

10 - 30 V DC (12 - 30 V DC for cable lengths above 110 m)

Output signal

2-wire 4 - 20 mA (passive transmitter)

Cable

2 × 0,5 mm

2

(pressure) + 5 x 0,15 mm

2

(data), shielded, PUR insulation

Cable length

12 m

12 m

12 m

12 m

12 m

35 m

110 m

320 m

Enclosure

IP 68, withstands a static pressure equal to max. overpressure.

Approvals

ATEX: II 2G EEx ia IIC T5/T6, CE: EN61000-6-3/-4:2001, EN61000-6-1/-2:1999,
EN50014:1997 E, EN50020:2002

Can be delivered with other cable lengths on request.

Advertising
This manual is related to the following products: