5a. Locate the actuator assembly (A) and the

two fillister head screws (B) which secure
it to the bearing of the control.

b. Clean the inspection lacquer out of the

screw slots in the two fillister head
screws.

c. Remove the two screws holding the actu-

ator assembly in place using a flat head
screwdriver. Remove actuator assembly
and place aside for reinstallation.

C

C

6. Remove the two Torx

®

screws (C) holding

the switch bracket assembly in place using
a flat head screwdriver or a Torx

®

T30

wrench.

7. Take the new switch bracket assembly

out of the package and place the bagged
supplies to one side while discarding the
insert.

Terminal Connection

Product

Switch

1

2

4

5

6

2 Wire

Blue

Orange

42S

Pump

2 Wire

White

Red

Burner

Terminal Connection Reference Chart