Xylem MM 613F Series FS4-3T General Purpose Liquid Flow Switch User Manual

Page 6

Advertising
background image

6

d. Based upon the mode of operation (“Flow” or “No-

Flow”) required, complete the appropriate steps to

connect wires to flow switch. Use a phillip’s head

screwdriver to loosen and tighten switch terminal

screws when attaching wires.
For “Flow” Mode of Operation (Fig. 1)

If the flow switch will be used to actuate a signal,

alarm or other device when

flow occurs, connect

the wire from that device to the “N.O.” contact.

Connect the “Hot” power supply wire to “C” terminal.
For “No Flow” Mode of Operation (Fig. 2)

If the flow switch will be used to actuate a signal,

alarm or other device when

no flow occurs, connect

the wire from that device to the “N.C.” contact.

Connect the “Hot” power supply wire to “C” terminal.

FLOW

OPENS

CIRCUIT

FLOW

CLOSES

CIRCUIT

COMMON

1

2

3

Flow

Opens

Circuit

Normally

closed

3

Common

1

Flow

Closes

Circuit

2

(

(

Normally

open

(

(

Common

(

(

FS4-3

LINE

LOAD

Fig. 1

HOT

3

1

2

FS4-3

LINE

LOAD

Fig. 2

HOT

3

1

2

c. Determine which switch action is required for the

flow switch.
• “Flow” means that the switch will close circuit

C.-N.O. and open circuit C.-N.C. when flow rate

is increased above setpoint of flow switch.

• “No Flow” means that the switch will open circuit

C.-N.O. and close circuit C.-N.C. when flow rate

is decreased below setpoint of flow switch.

Advertising