Barometric Pressure Sensor
a. Barometric Pressure sensor specifications.

Output:

4-19mA

Range:

800-1100 millibars

Accuracy:

+1% of full scale

Operating Voltage:

10-36VDC

Current Draw:

Same as sensor output

Warm Up Time:

3 seconds minimum

Operating Temperature: -40° to +55°C

Size of Probe:

3”x2”x1”

Weight:

.13 lb.

b. The sensor is a two-wire sensor using the red wire for power and the

black wire for the output signal. Warning: Always connect the

sensor with the power turned off.


c. The barometric pressure sensor may be stored without any special

provisions. Place the sensor inside a bag to keep the sensor clean

and store on a shelf or hang it on a wall.

d. When you read a barometer the reading directly from it is the "station

pressure."

Two things affect the barometer's reading, the high or low air pressure

caused by weather systems, and the air pressure caused by the

station's elevation, or how high it is above sea level. No matter what

weather systems are doing, the air's pressure decreases with height. If

you're trying to draw a weather map of air pressure patterns, you need

a way to remove the effects of the station's elevation. That is, you want

to see what the pressure would be at the station if it were at sea level.

You need to calculate, sea-level pressure, which is defined as: "A

pressure value obtained by the theoretical reduction of barometric

Advertising