Vii. wind direction sensor – Xylem WE100 BAROMETRIC PRESSURE TRANSMITTER User Manual

Page 9

Advertising
background image

Global Water

800-876-1172

globalw.com

- 9 -

VII. Wind Direction Sensor

a. Wind Direction sensor specifications.

Output:

4-19 mA

Range:

0 to 360° (352° electrical, 8° open)

Accuracy:

1% of full scale

Operating Voltage:

10-36VDC

Current Draw:

Same as sensor output

Warm Up Time:

3 seconds minimum

Operating Temp:

-40° to +55°C

Size:

8 ½” diameter x 10 ½” long

Weight:

1 lb.

b. The sensor is a two-wire sensor using the red wire for power and the

black wire for the output signal. Warning: Always connect the

sensor with the power turned off.


c. The ridge on the fixed portion of the sensor represents the 0° direction

of the sensor. The sensor comes with a stainless steel elbow that can

be mounted on a 1” diameter tube. For best results ensure that the

sensor is mounted parallel to the ground surface.

d. A wind direction sensor produces a ratiometric voltage signal. That

voltage signal is transformed into a 4-19 mA sensor output signal.

Advertising
This manual is related to the following products: