Vi. wind speed sensor – Xylem WE100 BAROMETRIC PRESSURE TRANSMITTER User Manual

Page 8

Advertising
background image

Global Water

800-876-1172

globalw.com

- 8 -

VI.

Wind Speed Sensor
a. Wind Speed sensor specifications.

Output:

4-20mA

Range:

0-110 MPH

Accuracy:

.2 MPH over the range 11 to 55 MPH

Operating Voltage:

10-36VDC

Current Draw:

Same as sensor output

Warm Up Time:

3 seconds minimum

Operating Temp:

-40° to +55°C

Size of Probe:

7” diameter x 8 ½” long

Weight:

1 lb.

b. The sensor is a two-wire sensor using the red wire for power and the

black wire for the output signal. Warning: Always connect the

sensor with the power turned off.


c. The sensor comes with a stainless steel elbow that can be mounted on

a 1” diameter tube. For best results ensure that the sensor is mounted

parallel to the ground surface.

d. The wind speed sensor or anemometer produces a sine wave voltage

signal with a frequency that changes linearly with the wind speed. The

frequency is transformed into a 4-20 mA sensor signal output.









Advertising