Faults

Code no. for cause and method of repair

Discharge too low

1, 4, 6, 7, 8, 9, 10, 11, 12, 13, 14

Discharge stops after a time

8, 10, 11, 21

Head too low

2, 4, 6, 7, 8, 9, 10, 11, 12, 13, 14, 21, 24

Head too high

3, 5, 24

Drive mechanism overloaded

2, 3, 5, 14, 17, 19

Pump not running quietly

7, 10, 13, 15, 16, 17, 20, 21, 23

Temperature in the pump too high

7, 10, 21

Temperature at the bearing too high

2, 3, 16, 17, 18, 20, 22

Meaning of code number for cause and method of repair

1.


Back-pressure too high

open discharge valve further

reduce resistance in discharge pipe (e.g. clean filter if necessary)

use larger impeller (note available motor power)


2.


Back-pressure too low, discharge too low

throttle discharge valve


3.


Speed too high

reduce speed

compare speed of motor with specified pump speed (rating plate)

when adjusting speed (frequency transformer) check reference value setting


4.


Speed too low

increase speed (check available motor power)

compare speed of motor with specified pump speed (rating plate)

when adjusting speed (frequency transformer) check reference value settings


5.


Impeller diameter too large

use smaller impeller


6.


Impeller diameter too small

use larger impeller (check available motor power)


7.


Pump and/or pipes not completely filled with liquid

fill

vent


8.


Pump blocked

clean