Operating instructions

WTS 102/3-en

16

9.

Air pocket in pipeline
•

vent

•

improve course of pipe


10.


NPSH of system too small
increase liquid level


11.


Air being sucked in
•

increase liquid level


12.


Direction of rotation is wrong
•

swap over two phases of power supply (to be done by a specialist electrician)


13.


Inner components suffering from wear
•

replace worn parts


14.


Density and/or viscosity of liquid handled is too high
•

seek assistance


15.


Impeller out of balance
•

remove blocks/deposits

•

replace if broken or unevenly worn

•

check shafts to ensure that they are running true


16.


Coupling distance too small
•

change


17.


Forces in pipeline too high (pump unit under strain)
change (support pipes, use compensators, etc.)


18.


Too much, too little or the wrong type of lubricant
•

change


19.


Electricity supply not right
•

check voltage of all phases (2-phase running)

•

check cable connections

•

check fuses


20.


Bearing damaged
•

replace

•

check lubricant and bearing space for pollutants (rinse oil area)


21.


Discharge too small
•

increase minimum amount carried (open slide valves, bypass)