Operating instructions

WTS 102/3-en

16

9.

Air pocket in pipeline

vent

improve course of pipe


10.


NPSH of system too small
increase liquid level


11.


Air being sucked in

increase liquid level


12.


Direction of rotation is wrong

swap over two phases of power supply (to be done by a specialist electrician)


13.


Inner components suffering from wear

replace worn parts


14.


Density and/or viscosity of liquid handled is too high

seek assistance


15.


Impeller out of balance

remove blocks/deposits

replace if broken or unevenly worn

check shafts to ensure that they are running true


16.


Coupling distance too small

change


17.


Forces in pipeline too high (pump unit under strain)
change (support pipes, use compensators, etc.)


18.


Too much, too little or the wrong type of lubricant

change


19.


Electricity supply not right

check voltage of all phases (2-phase running)

check cable connections

check fuses


20.


Bearing damaged

replace

check lubricant and bearing space for pollutants (rinse oil area)


21.


Discharge too small

increase minimum amount carried (open slide valves, bypass)