Operating instructions, Wts 102/3-en, Specification diagram – Xylem WTS User Manual
Page 9: Characteristic curves: capacity [m3/h
![background image](/manuals/311429/9/background.png)
Operating instructions
WTS 102/3-en
7
Specification Diagram:
2
Installation depth 900 mm
3
Installation depth 1400 mm
4
Installation depth 1900 mm
5
Installation depth 2400 mm
6
Installation depth 2900 mm
7
Installation depth 3400 mm
1
2
4
Characteristic curves
5
6
-
Standarddesign
1
Industrial design, medium lubricated slide bearings
2
Industrial design, pure water lubricated slide bearings
3
Industrial design, grease lubricated slide bearings
W T S
1
8
Code no for impeller, approx. diameter in cm
E
Sealing with radial packing ring and gease chamber
N N
Cast iron
S S
Bronze
V V
Cast steel alloyed
1
1
0
Motor power in 1/10 kW
4 Normal speed 1450 min-1
6 Normal speed 960 min-1
*) not required for normal cast iron model
Characteristic curves: