Operating instructions, Wts 102/3-en, Specification diagram – Xylem WTS User Manual

Page 9: Characteristic curves: capacity [m3/h

Advertising
background image

Operating instructions

WTS 102/3-en

7

Specification Diagram:





















2

Installation depth 900 mm

3

Installation depth 1400 mm

4

Installation depth 1900 mm

5

Installation depth 2400 mm

6

Installation depth 2900 mm

7

Installation depth 3400 mm

1

2

4

Characteristic curves

5

6

-

Standarddesign

1

Industrial design, medium lubricated slide bearings

2

Industrial design, pure water lubricated slide bearings

3

Industrial design, grease lubricated slide bearings

W T S

1

8

Code no for impeller, approx. diameter in cm

E

Sealing with radial packing ring and gease chamber

N N

Cast iron

S S

Bronze

V V

Cast steel alloyed

1

1

0

Motor power in 1/10 kW

4 Normal speed 1450 min-1

6 Normal speed 960 min-1

*) not required for normal cast iron model


Characteristic curves:




Capacity [m3/h]

Advertising