Extron Electronics DXP DVI Pro Setup Guide User Manual
Page 26
Advertising

20
DXP DVI Pro and DXP HDMI Series • Operation
3.
To change a value, press and release the button that relates to the
desired value:
C O N T R O L
I / O
Press and release the buttons to configure the RS-232/RS-422 port as follows:
Baud rate:
Enter — 9600
Preset — 19200
View — 38400
Esc — 115200
Serial protocol:
Video — RS-232 Audio — RS-422
The selected buttons blink and the others remain lit.
In this example, the port is set to RS-422 at 38400 baud.
AUDIO
ESC
VIEW
ENTER PRESET
VIDEO
Figure 19.
RS-232/RS-422 and Baud Rate Selection
4.
Press and release an output button to exit the Serial Port
Configuration mode.
Advertising