Cabling the enclosure, E. see “cabling the enclosure” in this chapter, Installation, cont’d – Extron Electronics HSA 400 & HSA 402 User Guide User Manual

Page 11

Advertising
background image

HSA 400/402 Series • Installation

HSA 400/402 Series • Installation

Installation, cont’d

2-8

3

.

Insert each of the AAP’s screws through the holes in the

AAP opening of the front panel. Secure each AAP to the

panel with the provided captive washers and #4-40 nuts

(figure 2-5).

Cable

#4-40 Nut with Captive

Washer

Front Panel

RGB 580xi SI AAP

HSA 400

125 50/60 Hz 0.5A

COMPUTER

INPUT

SELECT

AUDIO

Figure 2-5 — Mounting an AAP device to an HSA 400
US front panel

4

.

Replace the front panel in the surface mount enclosure and

secure it in place with the hex head screws removed in

step 2. If you lose a front panel screw, two spare screws

are stored in the underside of the clamshell.

Cabling the Enclosure

HSA 400

120-240 50/60 Hz 5A

H. SHIFT

COMPUTER

INPUT

SELECT

AUDIO

RGB 580

xi

SI AAP

1A

1B

2

3

Underside View

Front Panel View

1A 1B

Figure 2-6 — HSA 400 enclosure underside features

2-9

Advertising