Replacing the Gas Lift

The gas lift that raises the HSA surface is rated for 100,000

opening and closing cycles. Contact the Extron S

3

Sales &

Technical Support Hotline at the nearest phone number listed

on the rear cover of this manual to obtain a replacement gas lift.

Replace the gas lift as follows:

Ensure that AC power is disconnected before
servicing the HSA unit.

CAUTION

When the HSA 400/402 is upside-down, the latch
may be ineffective. If the latch releases, the enclosure
will tip and could damage the flanged edges. Keep a
hand on the enclosure to keep it from tipping.

1

.

Remove the surface mount enclosure from the table. See

“Removing and Replacing the Enclosure”, steps 1 through 8.

Place the enclosure upside-down on a horizontal surface.

To protect the finish, place the enclosure on a soft cloth.

2

.

Loosen the three Phillips head screws that secure the gas

lift mounting plate in place (figure 3-6).

Slide plate back,
then lift straight up.

Loosen (3)
screws.

Figure 3-6 — Releasing the gas lift

3

.

Slide the gas lift mounting plate toward the center of the

enclosure, releasing the mounting plate from the enclosure

(figure 3-6).

4

.

Turn the gas lift mounting plate counterclockwise until the

pivot nut on the plate comes free from the shaft of the gas

lift (figure 3-7).

Flange and
Top Panel
Assembly

Lower
Enclosure

Top Panel

Bracket

Gas Lift
Mounting Plate

Clevis

Pivot Nut

Gas Lift

Piston End

Figure 3-7 — Replacing the gas lift

5

.

Turn the surface mount enclosure onto its back side and

open the top panel.

With the gas lift disconnected, the top panel must be
manually lifted.

6

.

Remove and retain the 9/32" nut and bolt that secure the

gas lift to the top panel clevis. Pull the gas lift out of the

enclosure.

7

.

Insert the piston end of the replacement gas lift through

the hole in the bottom of the enclosure adjacent to the

latch, and secure the lift in the clevis on the top panel with

the nut and bolt that were removed in step 6.

8

.

Thread the pivot nut on the gas lift mounting plate onto

the shaft of the gas lift and tighten it several turns.

9

.

Firmly push the gas lift mounting plate into position on

the underside of the enclosure, engaging the three

mounting screws with the holes in the plate. Holding the

plate in position, secure it to the enclosure with the three

screws that were loosened in step 2.

10

. Reinstall the surface mount enclosure. See “Removing and

Replacing the Enclosure”, steps 11 through 17.