Replacing an aap, Maintenance and modifications – Extron Electronics HSA 400 & HSA 402 User Guide User Manual

Page 15

Advertising
background image

Maintenance and Modifications

HSA 400/402 Series • Maintenance and Modifications

HSA 400/402 Series • Maintenance and Modifications

3-2

The HSA surface mount enclosures can be modified in the

future to replace an AAP or to change the color or appearance of

the bezel plug-ins. The most probable corrective maintenance

procedures required are leveling the top surface and adjusting

its height and replacing the gas lift. Most of the maintenance

procedures require removing the surface mount enclosure from

the table.

Replacing an AAP

Replace one or more AAPs as follows:

Ensure that AC power is disconnected before
servicing the HSA unit.

1

.

On the underside of the clamshell and in the enclosure, cut

the tie wraps that route the AAP cables out of the way.

2

.

Remove the four hex head screws on the right and left

sides of the front panel (figure 3-1). Retain the screws. Lift

the panel away from the enclosure.

Remove two

Allen screws on each side.

Lift panel out
of enclosure.

125 - 50/60 H

z 5A

HSA 400

H. SHIFT

COMPUTER

INPUT

SELECT

AUD

IO

RGB 580

xi SI AAP

Figure 3-1 — Removing the front panel

3

.

Disconnect any cables from the rear of the AAPs that are to

be replaced. If a cable is no longer required in your

system, carefully pull the cable out through the bottom of

the surface mount enclosure and the clamshell.

4

.

Remove the AAP(s) to be replaced from the front panel by

unscrewing the nuts on the rear of the panel that fasten the

plates to the faceplate (figure 3-2).

Cable

#4-40 Nut with Captive

Washer

Front Panel

RGB 580xi SI AAP

HSA 400

125 50/60 Hz 0.5A

COMPUTER

INPUT

SELECT

AUDIO

Figure 3-2 — Mounting an AAP device

5

.

Cable the rear of the AAPs to be installed before attaching

the AAPs to the enclosure. Route the cables through the

hole in the underside of the surface mount enclosure and

connect them to the rear of the AAPs. If applicable, refer

to the cabling information in the AAP documentation.

6

.

Insert each AAP’s screws through the holes in the AAP

opening of the front panel. Secure each AAP to the

enclosure with the provided captive washers and #4-40

nuts.

7

.

Replace the front panel in the surface mount enclosure and

secure it in place with the hex head screws removed in

step 2. If you lose a front panel screw, two spare screws

are stored in the underside of the clamshell.

8

.

To prevent wear and tear caused by cable movement,

secure the AAP cables underneath the table. See “Routing

the AAP Cables” in chapter 2, “Installation”.

3-3

Advertising