Preparing the Routing Template

Extron offers a metal template for each HSA model.

Appendix A lists the HSA 400/402 template part numbers.

Extron recommends using this template as a guide to cut the

hole in the table where the HSA will be installed.

The metal routing template is reusable. Do not discard
this template when the installation is complete. Save it
for installing future HSA enclosures of the same size.

1

.

Cut two 1/2" x 4" (approximately 13 mm x 102 mm) strips

of soft, finished lumber at least long enough to span the

distance between the desired installation location on the

table or other mounting surface and the edges of the

mounting surface (figure 2-1).

CAUTION

Do not allow the wood screws to protrude through
the bottom of the wooden strips. Protruding screws
will mar the table when the template is used.

Mounting
Surface
Edge

Mounting
Surface
Edge

Wood Thickness
0.5" / 1.3 cm

Width of Mounting Surf

ace

Routing Template

Wood Strip
Height
4" / 10.2 cm

Minimum
4 Screws

Wood
Strips

Figure 2-1 — Prepared mounting template

These strips raise the routing template above the mounting

surface to provide room for the router’s collar, protect the

mounting surface, and extend the routing template’s reach

so that it can be clamped to the edge of the surface.

2

.

Using four or more short wood screws, secure the

mounting template to the lumber strips.

Installation Overview

Install and set up the HSA surface access enclosure as follows:

1

If you have an unprepared mounting template, prepare

the template. See “Preparing the Routing Template” on

the next page.

2

If desired, install the optional RJ-45 to RJ-11 conversion

kit(s) to replace one or more RJ-45 connectors with RJ-11

connectors. Refer to the RJ-45 to RJ-11 Conversion Kit

manual.

3

If desired, install the optional flexible conduit kit to

replace the removable AC power cord. Refer to the
Flexible Conduit Kit

manual.

4

Cut a hole in the surface where the enclosure will be

installed and install the enclosure. The clamshell clamps

the enclosure to the table. See “Preparing the Table and

Mounting the Enclosure” in this chapter.

5

Run all cables necessary to support the AC and RJ-45

connectors and all planned AAP connectors. Leave

enough slack in the cables to connect them to the

underside of the enclosure or to the rear of the AAPs

before the AAPs are installed in the enclosure.

6

Turn off all of the equipment to be connected. Ensure that

the equipment connected to the RJ-45 connectors and the

connections for any AAPs are all turned off and

disconnected from the power source.

7

If applicable, connect cables to the rear connectors on the

AAPs to be installed in the HSA. Install the desired AAPs

on the front panel of the enclosure. See “Cabling and

Installing the AAPs” in this chapter.

8

Connect the power and RJ-45 cables to the underside of

the enclosure. See “Cabling the Enclosure” in this chapter.

9

Route and secure the AAP cables inside the clamshell.

See “Routing the AAP Cables” in this chapter.

10

Peel the protective coating from the top surface.

11

Connect the power cords and turn on the devices that

connect to the surface access enclosure.