Program Audio Output

Connecting the 5-pole captive screw stereo output connector

Balanced or unbalanced program audio output is available on the MPS 602 using a 3.5 mm,
5-pole captive screw connector. Refer to the following illustration for proper wiring.

ATTENTION: For unbalanced audio output, connect sleeves to the center ground pin.

DO NOT connect sleeves to the negative (–) contacts.

NOTE: Do not tin the audio leads. Tinned wires are not as secure in the connector and

could be pulled out.

Do not tin the wires!

Balanced Audio Output

Tip

Ring

Tip

Ring

Sleeves

Unbalanced Audio Output

Tip

No Ground Here

No Ground Here

Tip

Sleeves

LR

LR

Figure 7.

3.5 mm, 5-pole Captive Screw Audio Output Connectors

n

Variable audio output — This 5-pole 3.5 mm captive screw connector outputs the
program audio.

NOTE: The variable audio output level is controlled by the front panel volume

encoder.

o

Mic Mix — One potentiometer controls the mic/line input level (

l

) mixed into the fixed

audio output (

p

).

L

R

SIG LINK

DTP IN

SIG LINK

DTP OUT

50/60 Hz

100-240V 1.0A MAX

1

2

RGB OUT

HDMI

MIC

MIX

RS-232

MPS 602 SA

Tx Rx G

MUTE HDMI AUDI

O

PHANTOM POWE

R

SELECT

3

4

5

6

OUTPUTS

AMP OUT

REMOTE

OVER DTP

OVER DTP

RS-232 IR

Rx G

Tx

Tx Rx

RS-232 IR

Rx G

Tx

Tx Rx

CLASS 2 WIRING

8Ω / 4Ω

INPUTS

AUDIO IN

AUDIO OUT

L 1 R

L 2 R

L 3 R

L

VARIABLE

R

L

FIXED

R

L 4 R

L 5 R

MIC LINE

R

k

n

o p

s

a

b

c

d

g

h i j

f

q

e

l m

r

Figure 8.

Mic Mix Level Control

p

Fixed audio output — This 5-pole, 3.5 mm captive screw connector outputs balanced
or unbalanced fixed level program audio output. The front panel volume encoder
does not control the audio level from this audio output port.

q

Amplified output (MA and SA models only)
MA models
— One green 2-pole, 5 mm locking captive screw connector for mono 70V
output.
SA models — One green 4-pole, 5 mm locking captive screw connector for amplified
dual channel output to a 4 or 8 ohm speaker system.

AM

P OU

T

CLA

SS

2

WIR

IN

G

70

V

L

R

AM

P OUT

CLA

SS

2 W

IRIN

G

8Ω

/ 4Ω

2

1

MPS 602 MA

MPS 602 SA

2

1

1

Strip and insert the speaker wires into the

connector and tighten the captive screws.
Be sure to observe the correct polarit

y.

2

Insert the wired connector into the amplifier

output and secure the locking screws on
either side.

Do not tin the wires!

Figure 9.