Preliminar y, Programming and control, cont’d – Extron Electronics MLC 104 SIS Programming and Control User Manual

Page 16

Advertising
background image

SIS

Programming and Control, cont’d

MLC 104 Series • SIS

Programming and Control

5-16

PRELIMINAR

Y

Command/r

esponse table for SIS commands (continued)

Command

ASCII

(T

elnet)

URL Encoded (W

eb)

Response

Additional description

(host to switcher)

(host to switcher)

(switcher to host)

Digital input data port (power sense port)

An input voltage below 1.2 VDC is considered to be logic low

. An input voltage above 1.2 VDC is consider

ed to be logic high.

These thr

esholds are not adjustable.

Set the input (I) mode

24

2*

X4

0

[2

%

2A

X4

0

%5B

Iom 2*

X4

0

Set the input/output mode (

X4

0

).

X4

0

=

0 = input (default)

8 = power sensor

When set for power sensor

, the input state is

triggered when the input pulse starts or

stops at the power sense port.

V

iew the digital input mode

2[

2%5B

X4

0

V

iew the digital input state

2]

2%5D

X4

3

= digital input state:

0 = off

1 = on

Firmwar

e

version, part number & information r

equests

Query firmwar

e version number

Q

or

1Q

Q

or

1Q

X1

1

Show the MLC’s firmware version (

X1

1

)

to two decimal places. This query yields the

number of the currently running version of

the user-updatable firmware

.

Example:

1Q

1Q

1.01

Query verbose version information

0Q

0Q

{r

esponse from 2Q}–{r

esponse from 3Q}–{r

esponse from 4Q}

Show the bootstrap, factory-installed, and

updated firmwar

e versions. See 2Q, 3Q, and

4Q below

.

Example:

0Q

0Q

1.03

-1.00(1.18-MLC104 -Thu, 20 Jan 2005 09:41:47 GMT)-1.00*(1.18-MLC104

-Thu, 15 Sep 2005 22:42:14 GMT)

Query bootstrap firmwar

e version

2Q

2Q

X1

1

The bootstrap firmware is not user-

replaceable, but you may need this

information during troubleshooting.

Example:

2Q

2Q

1.03

Query factory firmwar

e version

3Q

3Q

X1

1

(kernel version–model description–date time of upload)

Factory-installed firmwar

e is dif

fe

rent fr

o

m

the bootstrap firmwar

e, but it is also not user

-

replaceable. This firmwar

e was installed at

the factory; it is the version the

co

n

tr

oller

reverts to after a mode 1 r

eset (see chpt. 2).

Example:

3Q

3Q

1.00(1.18-MLC104 -Thu, 20 Jan 2005 09:41:47 GMT)

In this example the factory firmware version

is 1.00 and the IP Link kernel version is 1.18

for the

MLC

104,

dated

20 January 2005

.

Advertising