Preliminar y, Programming and control, cont’d, Mlc 104 series • sis – Extron Electronics MLC 104 SIS Programming and Control User Manual

Page 26: Programming and control 5-26

Advertising
background image

SIS

Programming and Control, cont’d

MLC 104 Series • SIS

Programming and Control

5-26

PRELIMINAR

Y

Command/r

esponse table for SIS commands (continued)

Command

ASCII

(T

elnet)

URL Encoded (W

eb)

Response

Additional description

(host to switcher)

(host to switcher)

(switcher to host)

Send e-mail file named in mailbox

24

Esc

X4

5

SM

W

X4

5

SM

|

Eml

X4

5

Send a dif

ferent e-mail file (one not named in the mailbox)

24

Esc

X4

5

,

X7

0

,

X4

7

SM

W

X4

5

%2C

X7

0

%2C

X4

7

SM

|

Eml

X4

5

X7

0

= The number to insert into an email

message if a

____.eml

file has an embedded

server-side include “<!--#echo var =

“WCR|” -->” (the

Esc

command with

no parameters.) The numeral is a 16-bit

number to be employed as the user defines.

This is an optional parameter

. Use 0 as a

placeholder if the optional

X4

7

variable is

used but

X7

0

is not needed.

Set e-mail server IP

addr

ess and user domain name

24

Esc

X1

4

,

X1

5

CM

W

X1

4

%2C

X1

5

CM

|

Ipm•

X1

4

,

X1

5

X1

4

= IP

addr

ess (xxx.xxx.xxx.xxx). Leading

zeros ar

e optional in setting values.

X1

5

= E-mail domain name, e.g.,

extr

on.com

Read/view e-mail server IP

address and user domain name

Esc

CM

W CM

|

X1

4

,

X1

5

X1

4

= IP

addr

ess (xxx.xxx.xxx.xxx). Leading

zeros

ar

e suppressed in r

eturned values.

X1

5

= E-mail domain name, e.g.,

extr

on.com

Event contr

o

l

Start events

27

Esc

1AE

W1AE

|

Ego

Stop events

27

Esc

0AE

W0AE

|

Est

Query quantity of events r

unning

Esc

AE

WA

E

|

#####

The response is the quantity of currently

running events, and it includes leading

zeros. For example, if two events ar

e

running, the response is 00002

.

Set the event number (

X3

5

) to hook to fr

ont panel button pr

esses (har

dwar

e-script interactions)

24

Esc

X3

5

EN

W

X3

5

EN

|

Ehk

X3

5

If desired, use this command to designate an

event script (

X3

5

.EVT) to be used to track

and react to har

dware happenings and MLC

button presses.

X3

5

= event number (0 - 99). The default

value of

X3

5

after a system reset is 255.

This command is optional. Y

ou do

n

ot

have to use this command to set up the MLC. By default during configuration, the configuration softwar

e associates the mai

n event script

file (

0.EVT

) with hardware events and button pr

esses. Once that event file has been compiled, it is capable of r

eceiving information from

the MLC’

s r

egister that tracks hardware

actions and button presses. In r

esponse to a detected button press or other hardwar

e happening, the event script can then tell

the MLC to issue commands, or make some other

change. Y

ou would use this command only to associate a differ

ent event script file with tracking and r

esponding to hardware/bu

tton actions.