Preliminar y – Extron Electronics MLC 104 SIS Programming and Control User Manual

Page 17

Advertising
background image

5-17

MLC 104 Series • SIS

Programming and Control

PRELIMINAR

Y

Command/r

esponse table for SIS commands (continued)

Command

ASCII

(T

elnet)

URL Encoded (W

eb)

Response

Additional description

(host to switcher)

(host to switcher)

(switcher to host)

Query updated firmwar

e version

4Q

4Q

X1

1

(kernel version–model description–date time of upload)

Use this command to find out which version

of the firmware, if any was uploaded into

the controller after it left the factory

.

Example:

4Q

4Q

1.00*(1.18-MLC104 -Thu, 15 Sep 2005 22:42:14

GMT)

In this example the current firmware version

is 1.00, the IP Link kernel version is

1.18, for

the MLC 104, dated 15 September

, 2005.

In a query response, an asterisk (

*) after the version number indicates the version that is curr

ently used.

A

question mark (

? or

?.??

) indicates that the factory default firmwar

e is the only firmware loaded in the switcher

.

A

carat (

^

) indicates the version of firmware that should be running, but, since a mode 1 reset was performed, the factory default firmwa

re

version is loaded and running instead.

An exclamation point (

!) indicates that the firmware is corrupted.

Query FPGA version

3

2Q

32

Q

X1

1

Show the field-programmable gate array

(FPGA) firmware version to two decimal

places (x.xx).

Request the MLC’s part number

N

N

60-xxx-00

Show the MLC’s part #. 60-573-00 =

MLC 104 IP

, 60-665-00 = MLC 104.

Request

A/V input number

I

I

Chn

X200

Show which input is active (selected).

X200

is the input number

.

Request the model name

1I

1I

MLC 104 IP

or MLC 104

Request the model description

2I

2I

MLC 104 w/ IP

MLC 104 with IP contr

ol.

Request system memory usage

3I

3I

# bytes used out of # of kbytes

Show amount of memory used and total

available memory for system operations.

Request user memory usage

4I

4I

# bytes used out of # of kbytes

Show amount of user memory used and

total available user memory

.

Example:

4I

4I

217856 Bytes Used out of 7232 KBytes

Request status of attached har

dware

32

I

32

I

P1##•P2##•K1##•K2##•K3##•K4##•S

Show the absence of or types of connected

devices.

For ##:

00 =

n

o

t pr

ese

nt

* 00

is

the val

u

e (##) for K1, K2, K3, a

n

d K4 for

the MLC 104

S

er

ies beca

u

se

they do

n

o

t s

u

ppor

t

co

nt

ro

l mod

u

les (IRCMs, ACMs, CCs, RCMs)

For :

00 =

n

o

t pr

ese

nt

01 = ML

S

306

02 = ML

S

506

03 = ML

S

506 MA

70 V

04 = ML

S

506

S

A

05 = ML

S

506 MA

100 V

06 = ML

S

100 A

07 = ML

S

103 V

Prefixe

s for connected device

s:

P1 =

S

CP

#1, addr

ess 0

P2 =

S

CP

#2, addr

ess 1

K1 =

co

nt

rol mod

u

le #1, addr

ess 0

*

K2 =

co

nt

rol mod

u

le #2, addr

ess 1

*

K3 =

co

nt

rol mod

u

le #3, addr

ess 2

*

K4 =

co

nt

rol mod

u

le #4, addr

ess 3

*

S

=

Med

iaL

in

k dev

ice,

typ

ically

a slaved ML

S

sw

it

cher

.

08 = ML

S

103

S

V

09

= ML

S

102 VGA

10 = MLA-VC10

11

=

M

L

S

304 MA

12 = ML

S

406

13 = ML

S

406 MA

14 = ML

S

406

S

A

15 = ML

S

304

S

A

Advertising