Preliminar y – Extron Electronics MLC 104 SIS Programming and Control User Manual
Page 7

5-7
MLC 104 Series • SIS
™
Programming and Control
PRELIMINAR
Y
X208
= Display (projector on/off) status as tracked by the
display driver
0 = display power is off
1 = display power is on
2 = display is powering down/off (cooling
down)
3 = display is powering up/on (warming up)
X209
= Front panel lockout (executive mode ) status
0 = off/unlocked (default)
3 = on, disable/lock entire front panel (buttons,
volume control) and optional connected SCP
X210
= IR/serial port configuration
0 = IR ports (0 V – 5 V) (default)
1 = RS-232 ports (±5 V)
X211
= Status (in hexadecimal characters) of script or
firmware button control
.
This variable is an 8-
digit hexadecimal character calculated from a
binary bit map. See page 5-27 for details.
X212
= Status (in hexadecimal characters) of control of
lamp enabling (control of all button lights).
This variable is an 8-digit hexadecimal character
calculated from a binary bit map. See page 5-29
for details.
X213
= Power sensor status:
00
= power sensor is connected and is not
sensing projector power (detector voltage is low,
signal pin voltage is high)
01
= power sensor is connected and is sensing
projector power (detector voltage is high)
02
= power sensor is disconnected or sensor is
connected but the sensitivity is set too high
(voltage is low at both the detector and signal
pin)
X214
= Power sensor signal pin status
00 = voltage is low
01 = voltage is high
Leading zeros will be used in responses to
commands that use this variable.
X215
= IR/Serial Output port number
1 = projector port
X216
= Display mute or connection status
0 = off/disconnected
1 = on/connected
2 = unknown/unavailable