Installation

5.3 Connecting pipes

a) Vacuum connection at (Fig. 2/A, 3/A).

NOTICE

Damage to the threaded inlet connection

may result from excessive torque during the

installation of the process piping. Use only the

sufficient amount of torque to obtain a sealed

connection.

Small diameter and excessive length of piping

may reduce the pumping capacity. Contact

Engineering for pipe size recommendations.

b) The discharged air can be blown out through the

exhaust silencer at (Fig. 3/B) or conducted away
using a hose or a pipe.

NOTICE

The air vent (Fig. 3/B) must not be closed or

restricted.

Back pressure on the discharge port is only

permissible up to:
S-VSI (44) 10 Hp < 2.9 psi

Prevent liquids accumulating in the vertical

exhaust line by installing a drip leg.