Safety

2.3 Designated use

The pump must only be operated in such areas as
are described in the operating instructions:

• only operate the pump when it is in good

mechanical condition

• do not operate the pump when it is partially

assembled

• the pump must only be operated at an ambient

temperature and suction temperature of
between 41 and 104°F.
Please contact us for temperatures outside this
range.

• the pump may convey, compress or extract the

following media:

• all non-explosive, non-flammable, non-

aggressive and non-poisonous dry gases
and gas air mixtures

• in addition, may handle inlet gasses with

high humidity levels due to its excellent
water-vapor tolerances.

2.4 Unacceptable operating modes

• extracting, conveying and compressing

explosive, flammable, aggressive or poisonous
media, e.g. dust as per ATEX zone 20 –22,
solvents as well as gaseous oxygen and other
oxidants, water vapor, liquids or solid materials

• using the pump in non-commercial plants

where the necessary precautions and protective
measures have not been taken employed

• installing in environments that are at risk of

explosions

• using the pump in areas with ionizing radiation

• back pressures on the outlet side:

S-VSI (44) 10 Hp > + 2.9 psi

• Modifications to the pump and accessories