Elmo Rietschle S-VSI 300(44) User Manual

Page 33

Advertising
background image

33

www.elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

Final pressure (max.
vacuum) is not
reached

Pump or system vacuum
leaks

Check the pipe work and
screw connections for leaks
and to ensure that they are
firmly seated

Section 7.2

Insufficient cooling water

Note cooling water
consumption from data sheet

Section 9

The mesh filter is dirty

Clean or replace the mesh
filter

Section 7.2.2
Section 7.4

Pump gets too hot

Ambient or intake temperature
is too high

Recheck operating
parameters

Section 2.3

Cooling air supply is
obstructed

Check environmental
conditions

Section 5.1

Clean the cooling fins

Section 7.2

The cooling water system is
obstructed

Check the cooling water
system and the pipes

Section 7.2

Insufficient cooling water

Note cooling water
consumption

Section 9

Cooling water inflow is too hot Note the max. intake

temperature

Section 9

The pump makes a
abnormal noise

Deposits on the rotors

Clean the compression
chamber and the rotors

Elmo Rietschle
Service

Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.

Advertising