Malfunctions: Causes and elimination
Fault
Cause
Troubleshooting
Important
Pump is switched
off by the motor
protection switch
Power Supply/ Frequency
does not correspond with the
motor data
Check by qualified electrician
Section 5.5
Connection to motor leads is
not correct
Motor protection switch is not
set correctly
Motor protection switch is
triggered too quickly
Use a motor protection switch
with an overload-dependent
delayed switch off that takes
into consideration the short
term excess current at start
up
Pumping capacity is
insufficient
The mesh filter is dirty
Clean or replace the mesh
filter
Section 7.2.2
Section 7.4
The suction pipe is too long or
too narrow
Check the hose or the pipe
Section 5.3
Pump or system vacuum
leaks
Check the pipe work and
screw connections for leaks
and to ensure that they are
firmly seated
Section 7.2
8