Installation and Commissioning

© Gardner Denver Deutschland GmbH

15 / 30

610.44431.40.000

The scope of supply of the external electronics
(Drivecontrol VT-D) includes a connector with a
300 mm wiring harness to connect the Drivecon-
trol to the supply voltage and control voltage.

In order to meet the requirements bearing on
electromagnetic compatibility a suitable EMI
filter (e.g. CORCOM, Type 6ET1, 10A) must be
connected in series with the external-electronics.
The connecting cable between the EMI filter and
the G-BH100 must have a length of at maximum
0,3 m
.

5.2.1.2 G-BH100

with

integrated electronics

With this type the electronics is located inside the
motor.

i

IMPORTANT!
With the integrated-electronics type
G-BH100 the electronics is particu-
larly sensitive to overheating!
It is imperative to ensure sufficient
heat dissipation and cooling!

On delivery the integrated-electronics type G-
BH100 is not equipped with a connector at the
connecting cable. In this instance the operator
can, according to the requirements of the system,
connect a connector at his option, connect the
terminals to a terminal strip, etc.
The electrical connection is to be carried out:

 according to the applicable national and local

laws and prescriptions

 according to the applicable system-dependent

prescriptions and requirements

 according to the applicable prescriptions of

the utility company


Via the motor connecting cable the supply volt-
age as well as the different control signals are
applied to the integrated electronics.
For the assignment of the leads or strands please
refer to Fig. 8 as well as the following table.



Lead colour

Assignment

Cable
old version

Cable
new version

pink red +V

CC

yellow black Gnd
green green n

des

white white A
grey grey B
blue blue n

Ist

brown --

not

connected

red -- not

connected

Fig. 8: Connection of the integrated electronics type


G-BH100