Elmo Rietschle G-BH10 User Manual

Page 5

Advertising
background image

Intended Use

© Gardner Denver Deutschland GmbH

5 / 30

610.44431.40.000

These operating instructions
 must be completely read and understood by

all operating and servicing personnel before
beginning to work with or on the G-BH100,

 must be strictly observed,
 must be available at the site of operation of

the G-BH100,

 applies to Side channel blowers of the

G-Series G-BH100,

 contains instructions bearing on transport and

handling, installation, commissioning, opera-
tion, servicing, shut-down, and storage of the
G-BH100.


The operating and servicing personnel working
with or on the G-BH100:
 must be trained and authorised for the work to

be carried out.

 Work on electrical installations may be carried

out by trained and authorised electricians
only.


The G-BH100
 are single-stage gas-ring vacuum pumps /

compressors

 are machines used to generate vacuum or

overpressure

 are used to extract, to deliver and to com-

press the following pumped gases:

-

air,

-

other gases, which are not explosive,
flammable, aggressive or toxic

-

The pumped gases must not contain any
solid bodies or impurities; those must be
separated before entering the unit by
means of a filter.

 exist in six fundamental designs

1

:

-

2BH10 02-0AB32:
hose connection with enclosed motor
and integrated electronics

-

2BH10 02-0AB22:
hose connection with enclosed motor
and integrated electronics

-

2BH10 02-0AA53:
hose connection with enclosed motor
external electronics

-

2BH1002-1….: flange connection

 are intended for industrial applications.
 are designed for continuous operation; in case

of increased turn-on frequency or increased
intake and ambient temperature the limiting
overtemperature of the winding and the bear-
ings must not be exceeded
(operation only according to "Fig. 3", page 9).

1

In order to determine the design of your G-BH100

refer to the type number (MLFB) on the rating plate.

When operating the G-BH100 it is imperative to
observe the limiting values given in section 3,
"Technical Data".


Foreseeable Misuse

It is prohibited:
 to use the G-BH100 in applications other than

industrial applications,

 to use the G-BH100 in areas where explosive

atmosphere might occur,

 to extract, to deliver and to compress explo-

sive, flammable, aggressive or toxic fluids,

 to operate the G-BH100 with values other

than those given in section 3, "Technical
Data".


Any unauthorised modifications of the G-BH100
are prohibited for safety reasons.
Maintenance work is only allowed to the extent
described in these operating instructions.
Any further maintenance work as well as repair
work may only be carried out by companies
authorised by the manufacturer (please contact
your sales engineer).

i

IMPORTANT!
The G-BH100 is a component
intended to be incorporated in a
machine or system. It is delivered
for this purpose to manufacturers
of such machinery or systems
(OEMs) only.

i

IMPORTANT!
The installation of the G-BH100 in
your machine or system must be
carried out in keeping with the
requirements on electromagnetic
compatibility according to the
EMC Directive.

2 Intended

Use

Advertising