1 safety and residual risks – Elmo Rietschle G-BH10 User Manual

Page 3

Advertising
background image

Safety and Residual Risks

© Gardner Denver Deutschland GmbH

3 / 30

610.44431.40.000

Before beginning to work on the G-
BH100 or the system carry out the
following steps for both the G-BH100
and the entire system

switch off electricity,

lock against restart,

ensure absence of electricity,

ground and short-circuit instal-
lation,

cover or bar adjacent live
parts,

depressurise both pipes and
pump.

Do not wear long, loose hair! Use a
hair net! Never wear wide, loose
clothes!

Transport and handling as well as
assembly and disassembly may be
carried out by trained and responsi-
ble personnel only!

Operation of the G-BH100 only

with the gases as indicated in
section 2, "Intended Use"!

with the values as indicated in
section 3, "Technical Data"!

Check pipes/hoses and vessels for
sufficient strength!

Check pipe / hose connections for
tightness!

Operation of the G-BH100 only when
completely assembled and securely
fastened to the mounting surface!

Check fasteners for secure fixing at
regular intervals!

After loosening clampings and fas-
tening elements some parts and
components are only held in place
by their centrings or seatings or are
no longer held in place at all so that
they might fall down.
Take the necessary care during dis-
assembly and assembly!

Operation of the G-BH100 only with
the pump lid assembled!
Disassembly of the pump lid only
after the impeller has come to a
complete standstill!
Consider impeller run-out!

Operation of the G-BH100 only with
the pipes / hoses connected to the
suction and delivery branches!
WARNING!
In case of operation with open suc-
tion or delivery branches (drawing-in
of gases from or discharge of gases
into the surroundings) a piece of
pipe or hose with a length of at
least 120 mm
must by all means be
connected to the branch in question
in order to prevent the impeller from
being reached by fingers!
Disassembly of the pipes / hoses
connected to the suction and deliv-
ery branches only after the impeller
has come to a complete standstill!
Consider impeller run-out!

Do not reach into the G-BH100
through open suction or delivery
branches!
Do not insert any objects into the G-
BH100 through the openings!

Operation of the G-BH100 only with
the motor cap assembled!
Disassembly of the motor cap is
prohibited.

Work on electrical installations may
be carried out by trained and author-
ised electricians only!

The electrical connections must be
surrounded by a housing which is
proof against foreign bodies, humid-
ity, etc.!
Consider the life expectancy of the
seals and gaskets!

Ensure that no foreign bodies, hu-
midity, etc. enter the motor interior!

For heat dissipation and cooling pro-
vide a minimum distance of 15 mm
on each side except for the pump lid
side on which a smaller distance of
at least 2 mm is permissible!

Burning and scalding hazard due to
hot surfaces of the G-BH100!
Do not touch during operation! Let
the unit cool after shut-down!
Provide a guard against accidental
contact!

1 Safety and Residual Risks