Shutting Down and Measures for Prolonged Standstill

© Gardner Denver Deutschland GmbH

23 / 30

610.44431.40.000

i

IMPORTANT!
If the storage period exceeds one
year the life expectancy of the bear-
ings might be reduced.


Measures after shutdown / before storage:

 Seal up the suction and delivery branches.
 Provide loose lead ends with an ESD-

prevention bag.

 Ensure the correct storage conditions (see

below).



Storage conditions:

Ambient temperature

-20°C...+70°C
(-4°F…+158°F)

Relative humidity

10% ... 95%

Atmospheric pressure

500 hPa ... 1,100 hPa

Vibrations see

section

3,

"Technical

Data", page 6.


Measures before recommissioning after stor-
age:

 Make sure that there is no oxide layer on the

contacts. If necessary, remove oxide layer.

 Make sure that the insulation of the electrical

connecting cable has not become porous.