Installation and Commissioning

610.44431.40.000

16 / 30

© Gardner Denver Deutschland GmbH

Lead colour

Symbol Description

Level

Cable
old version

Cable
new version

+U

B

DC operating voltage

24 V (max. 28 V)

pink red

Gnd

DC operating voltage,
reference potential for all signals

0 V

yellow black

n

des

Speed reference value:
Reference value of the desired speed of
the G-BH100.

0 ... 10 V DC

green

green

n

act

Frequency output representing the actual
speed:
open collector signal which must be wired
to an external pull-up resistor.
Output frequency / motor speed ratio:
1 Hz = 10 min

-1

Open collector
max. 24 V / 10 mA

blue blue

A

white white

B

Control signals A and B are digital inputs.
Broad voltage-range input compatible with
TTL / PLC signals.
In all four possible combinations:

A B Function
0 0 Motor disabled (no current)
0 1 CCW rotation
1 0 CW rotation
1 1 Motor disabled

Low (0): < 0.5 V DC
High (1): > 4 V DC
max. 30 V DC

grey grey

-- not

connected

--

brown --

-- not

connected

--

red --


In order to meet the requirements bearing on
electromagnetic compatibility an EMI filter
from Messrs CORCOM, Type 6ETI F7003, 6A,
must be connected in series with the integrated-
electronics type G-BH100. The connecting cable
between the EMI filter and the G-BH100 must
have a length of at maximum 0.5 m.

i

IMPORTANT!
The main or operating direction of
rotation
of the G-BH100 is the
counter-clockwise rotation, given
by the arrow indicating the direction
of rotation on the pump lid.
Only with the counter-clockwise rota-
tion the nominal values will be achie-
ved.
Clockwise rotation is only permissi-
ble in special cases.
In this instance the G-BH100 will not
achieve its full output.

i

IMPORTANT!
The connecting cable between the
G-BH100 and the external electron-
ics must have a length of at maxi-
mum 0.5 m
!

i

IMPORTANT!

When switching off the G-BH100 or
rapidly reducing its speed a current
feed into the mains might occur.

This can be prevented by inserting a
diode (Schottky diode, size 6A) in
the 24-V supply lead (+U