Maintenance, 1 controller lithium battery replacement, 2 spare parts – Alpha Technologies CXDS-M 600_600-19 User Manual

Page 35

Advertising
background image

33

9400002-J0 Rev A

9. Maintenance

Although very little maintenance is required with Alpha systems, routine checks and adjustments are recom-

mended to ensure optimum system performance. Qualified service personnel should do the repairs.
The following table lists a few maintenance procedures for this system. These procedures should be performed

at least once a year.

Use extreme care when working inside the unit while the system is energized. Do not
make contact with live components or parts.

Circuit cards, including RAM chips, can be damaged by static electricity. Always wear a
grounded wrist strap when handling or installing circuit cards.

Ensure redundant BDFBs are used to eliminate the threat of service interruptions while
performing maintenance on the system alarms and control settings.

WARNING!

Table E — Sample maintenance log

Procedure

Date Completed

Clean ventilation openings.

Inspect all system connections. Re-torque if necessary.

Verify alarm/control settings.

Verify alarm relay operation.

9.1 Controller Lithium Battery Replacement

NOTE:

Replace the battery within 30 seconds to prevent loss of date and time.

A removable lithium battery is located near the back and to the right of the motherboard. The battery life is rated

up to three years, but replace earlier if the panel does not maintain date and time during power interruption.

WARNING!

Exercise extreme caution and do not touch any connected equipment.

To replace the lithium battery, shut down the CXC, remove the rear cover, and pull battery out carefully. Ensure

that the new battery is the same as the one being replaced.

9.2 Spare Parts

Description

Part #

Interface board

7050132-001

Slam latch

6470008

Advertising