Recommended oil – Alpha Technologies AlphaGen DCX2000 - Operator's Manual User Manual

Page 16

Advertising
background image

16

041-135-B0-001 Rev. A (07/2013)

2.0

Operation, continued

2.6 Operation at High Altitude

The standard carburetor air-fuel mixture will be excessively rich at high altitudes. This will decrease

performance and increase fuel consumption.
High altitude performance can be improved by installing a smaller diameter main fuel jet in the carburetor.

If you always operate the generator at altitudes higher than 5000 feet (1500 m) above sea level, have an

authorized Alpha Service Center install a high altitude main jet.
Even with suitable carburetor jetting, engine horsepower will decrease approximately 3.5% for each 1000

feet (305 m) increase in altitude. The affect of altitude on the horsepower will be greater than this if no

carburetor modification is made.

Have any carburetor modifications reversed before operating at lower altitudes. Operation of the

generator at an altitude lower than the carburetor is jetted for may result in reduced performance,

overheating, and serious engine damage caused by an excessively lean air/fuel mixture.

CAUTION!

2.7 Operation at Extreme Temperatures

High temperatures adversely affect generator operation.

Generator performance will decrease 1% for each 10°F

(5.5°C) increase in temperature above 85°F (29°C). The

normal operating range of this generator is 5° to 104°F (-15°

to 40°C). Although the generator can operate at 5°F (-15°C)

it will be necessary to use a lower viscosity engine oil such

as SAE 0W-40. Even with 0W-40 oil, the engine will be

more difficult to start.

When operating the generator below 5°F (-15°C), the unit may be difficult to start. In temperatures above

104°F (40°C), the output power will be derated.

CAUTION!

2.8 Engine Shutdown

To stop the engine in an emergency, push the engine switch on the control panel to the OFF position.

In an emergency, push the engine switch to the off position. This will stop the engine with or without a load.

However, repeatedly stopping the generator without disconnecting all loads may damage the generator or power

supply.

CAUTION!

Normal Shutdown Procedure:
1. Disconnect load.
2. Push the engine switch to the OFF position.
3. Turn the fuel valve to the OFF position.

Recommended Oil

SAE 0W-40

SAE 10W-40

0° F

32° F

113° F

(-18° C)

(0° C)

(45° C)

Fig. 2-8, Recommended Oil By Temperature

Fig. 2-9, Fuel Valve ON/OFF Positions

Advertising